Your analyzer already worked out the result. Stop retyping it.

Itzli installs a service on the laboratory’s PC that listens to your instruments, takes in every sample and drops it into the order it belongs to. You open the system and the result is already there, waiting for you to review it.

Does Itzli read your analyzer?

Type the brand and model. We tell you the truth even when the answer is no.

Quick:

How the result gets from the instrument into the order

01

The instrument finishes the sample

And sends it out the way it already knows how: over the network for the Mindray instruments, over a USB cable for the Spinreact. Nothing on the analyzer changes beyond its output settings.

02

The bridge picks it up

A Windows service that starts on its own with the machine. It writes every sample to an on-disk queue before it tries to upload: if the internet drops, nothing is lost — it goes up when the connection comes back.

03

It gets matched by folio

If you entered the order number — the folio — on the instrument, by scanning the label or typing it, the result lands in that order by itself. It accepts the full folio, OL-000123, or just the number.

04

What does not match is not lost

It lands in an unassigned-results tray, with its timestamp and its instrument, so you can send it to the right order from the panel. It is never silently discarded.

The evidence behind each claim

Which analyzers we read, and which ones should work

The bridge does not read brands: it reads two protocols, HL7 v2 and ASTM E1394, which is what nearly every clinical analyzer speaks. That opens the list up. But opening the list is not the same as having tested it, so here they are, kept apart.

Tested against the physical machine

Tested

Someone connected the bridge to these machines and watched them deliver specimens, with the instrument right there. It is the only rung where we say "we read it".

Tested against the physical machine — Analyzers by level of evidence: tested against the physical machine, and compatible by documented protocol
Analyzer Area Connection Evidence
Mindray BC-20s Hematology Network · HL7 over TCP Tested 2026-07
Mindray BS-240 Clinical chemistry Network · HL7 over TCP Tested 2026-07
Spinreact U120s Urinalysis Serial port · ASCII Tested 2026-07

They speak a protocol we already read

Untested

The manufacturer documents, in its own interface manual, that these analyzers speak HL7 v2 or ASTM E1394. We have not watched them read. We test it with your instrument, not with ours.

They speak a protocol we already read — Analyzers by level of evidence: tested against the physical machine, and compatible by documented protocol
Analyzer Area Connection Evidence
Mindray BS-240Pro Declared in: Manual de interfaz LIS BS-360E / BS-240Pro / BS-240E (Mindray): HL7 2.3.1 o ASTM E1394-97 sobre TCP/IP Clinical chemistry Network · HL7 over TCP Untested
Mindray BS-240E Declared in: Manual de interfaz LIS BS-360E / BS-240Pro / BS-240E (Mindray): HL7 2.3.1 o ASTM E1394-97 sobre TCP/IP Clinical chemistry Network · HL7 over TCP Untested
Mindray BS-360E Declared in: Manual de interfaz LIS BS-360E / BS-240Pro / BS-240E (Mindray): HL7 2.3.1 o ASTM E1394-97 sobre TCP/IP Clinical chemistry Network · HL7 over TCP Untested
Mindray BC-5150 Declared in: Documentación de producto Mindray BC-5150: LIS bidireccional con resultados e información del paciente, protocolo HL7 Hematology Network · HL7 over TCP Untested
Sysmex XN-550 Declared in: XN-550 series ASTM Host Interface Specifications (Sysmex): presentación ASTM E1394-97 sobre enlace E1381-02, TCP/IP Hematology Network · ASTM over TCP Untested
Sysmex XP-300 Declared in: XP Series ASTM Communication Specifications (Sysmex) Hematology Serial port · ASTM Untested
Roche cobas c111 Declared in: cobas c111 Host Interface Manual (Roche): ASTM E1394-97 en la capa alta sobre E1381-97 en la baja Clinical chemistry Serial port · ASTM Untested
Horiba Yumizen H500 Declared in: Documentación de interfaz Yumizen H500 (Horiba): ASTM LIS01-A2 y LIS02-A2 —los mismos E1381/E1394 renombrados por CLSI— por serie o Ethernet Hematology Network · ASTM over TCP Untested
Horiba ABX Micros ES60 Declared in: ABX Micros ES60 Technical Manual (Horiba): salida a LIS en formato ABX o ASTM por RS-232 (COM1) Hematology Serial port · ASTM Untested

What happens if your analyzer is in the second group

We connect it with you during the 30-day trial, with your instrument and your specimens. If we cannot get it to read, you decide: keep the system and enter that analyzer by hand — the way you do today — or walk away without paying anything.

And so that "reads" means the same thing to both of us

Reading means the parameters of the test arrive complete and match what your instrument prints, on your own specimens. It is not "it connected": an analyzer can connect and hand you half the analytes, or drop the decimals. That, to us, is not reading.

And if your analyzer is on neither list?

Look it up in the checker above. If it does not come back, send us the LIS interface manual for your instrument — the manufacturer provides it, and it states whether the analyzer speaks HL7 or ASTM — and within 48 hours we tell you yes, no, or we do not know. In writing, before you sign anything.

Send us the manual →
The fine print that actually matters. A manufacturer writing "HL7 v2" in its manual does not guarantee the reading works on the first try. HL7 v2 is a family of dialects: there are proprietary segments, the field order shifts, and every instrument names its tests differently. In ASTM the response timing and the checksum shape change. That is why the second group is not called "supported", and why we test it before charging you, not after.

Installation

Double-click, and that is it

From your laboratory’s panel you download an installer that already carries your configuration inside: your token, your instruments and their addresses. Nothing to type, and no technician has to come out to edit configuration files.

It installs as a Windows service

It starts with the machine. If somebody shuts down the front-desk PC and turns it back on, it carries on working without anyone opening it.

You configure it from the panel, not on the PC

You add an instrument or change its IP from the browser. The bridge picks that up in under a minute, with no reinstall.

You can watch it live

From Devices you see which instruments are connected, when the last heartbeat came in, and you can tell them to reconnect.

It holds up on a bad connection

On-disk queue, retries and an incident tray. A result that could not be uploaded does not disappear: it is logged for you to review.

Let us connect it in front of you

We bring the installer to your laboratory, plug it into your analyzer, and you run a sample. If your instrument is not one of the three, we tell you before we book anything.

  • We migrate your catalog, at no cost
  • 30-day trial on your real operation
  • If your cash drawer does not balance in 60 days, you do not pay

No commitment. Your data is handled under Mexico’s federal data protection law (LFPDPPP).